Also: CIP · automated cleaning

Automated cleaning circuit that flushes a closed system (tanks, pipes, HX, fillers) without disassembly — caustic, acid, rinse, sanitizer sequence.

Typical Hazards
  • B
    Biological
    Residual biofilm if temperature / flow / concentration inadequate
  • C
    Chemical
    Cleaner / sanitizer residue if rinse inadequate
Typical Controls
  • Validated CIP cycle: time, temperature, concentration, flow
  • Conductivity / pH check on rinse-water exit
  • Operator training and CIP record per circuit